Image for Illustration purposes only. Actual product may vary
Red Lion Controls TSC01001 TSCSTDAL1AL2ANL
MODEL TSC01001
Contact supplier for technical support on: 877-432-9908
$608.00 Each
Prices are subject to change
FREE SHIPPING ON ORDERS OVER $1
Select Quantity
Free Gift with this product
Typically Ships in: 1 day
Returnable: See conditions
Description
The TSC is a setpoint controller suitable for time vs. temperature, process control applications. The TSC accepts signals from a variety of temperature sensors (thermocouple and RTD elements), precisely displays the process temperature, and provides an accurate output control signal (time proportional or linear) to maintain a process at the desired control point. A comprehensive set of easy to use steps allows the controller to satisfy various applications. The user input can be programmed to perform a variety of controller functions.
Dual 4-digit displays allow viewing of the measured temperature value and setpoint or temperature and profile status simultaneously. Front panel indicators inform the operator of controller status and output states. Replaceable output modules (Relay, logic/SSR drive or Triac) can be fitted to the main control output, alarm output(s) or timed event output(s), and cooling output.
The TSC has been designed to simplify the set-up and operation of a controlled setpoint profile program. The setpoint program is easily entered and controlled through the front panel. Full display capabilities keep the operator informed of the process temperature, profile status, output states, and setpoint value.
The controller can operate in the standard PID control mode for both heating or cooling with on-demand auto-tune which establishes the PID gain set. The PID gain set can be fine tuned by the operator at any time or may be locked from further modification. The unit can be transferred to the manual control mode providing the operator with direct control of the output.
The TSC features four programs or profile recipes, each with up to eight ramp/soak segments, which can be easily stored and executed at any time. Longer profiles can be achieved by linking one or more profiles together, creating a single profile of up to 32 ramp/soak segments. Temperature profile conformity is assured during either soak (hold) phases or both ramp and hold phases by an adjustable error band parameter. The program repeat function cycles the profile either continuously or a set number of times. Power-on options automatically re-start, stop, or resume a running profile. The profile can be controlled via the front panel buttons, the user input, or the optional serial communications port. Four control points, each having a setpoint and PID parameter set, are available for instant front panel implementation during batch changeover, or other process conditions. A control point may have its PID gain set values disabled when implementing the control point.
Optional alarm output(s) may be configured to operate as a timed event output or as a standard alarm output. As an alarm output it may be configured to activate according to a variety of actions (Absolute HI or LO, Deviation HI or LO, or Band IN or OUT) with adjustable hysteresis. Also, a standby feature suppresses the output(s) on power-up until the temperature stabilizes outside the alarm region. Timed event output(s) allow the controller to activate other equipment while a programmed profile is running. Each profile can define up to 16 event states (phases), for each output(s).
The optional linear 4 to 20 mA or 0 to 10 VDC output signal is available to interface with final actuators, chart recorders, indicators, or other controllers. The output signal can be digitally scaled and selected to transmit one of the following:
Note: Output Modules are NOT supplied with the controller. When specifying the controller, be sure to purchase the appropriate output module for the Main Control Output and if necessary, the alarm output(s), the secondary output, and valve positioner outputs.
The Logic/SSR Drive Module is a switched DC source, intended to drive the DC input of an SSR power unit. It should never be connected to line voltage.
All modules are packaged separately and must be installed by the user.
Specifications
97 mm x 50 mm • Dual 4 Digit, 0. 4" (10 mm) LED, 0. 3" (7. 6 mm) LED • Thermocouple and RTD Input • Ramp/Soak • Event Outputs • Dual Alarms • Linear 4 - 20 mA Output
Accessories
BMK40000 | BMK4 Base Mount Kit for Apollo, Gemini, PAX, TCU, PCU, TSC, PSC and PXU |
---|---|
OMD00000 | OMD Relay Module for PCU, PSC, TCU and TSC |
OMD00001 | OMD Triac Module |
OMD00003 | OMD Logic/SSR Drive Module |
RLY50000 | RLY5 Solid State Power Unit |
RLY70000 | RLY7 Three Phase DIN Rail Mount Solid State Relay |
RLY60000 | RLY6 25 A Single Phase DIN Rail Mount Solid State Relay |
RLY6A000 | RLY6A 40 A Single Phase DIN Rail Mount Solid State Relay |
SKU: 286716
Arived with the readout actully working
This one worked. Second one I ordered, one from another supplier. First one was dead. Battery is supposed to last for 5 years, it's an "always on" setup. Mine first one did last the 5 years. I use this on my milling machine powered by a VFD.
Read moreWhen you get to checkout, you’ll be able to select a free gift! Depending on the cart value, you’ll be shown relevant gifts your order qualifies for.
$500
MRO Hat
MRO Golf Balls
MRO Hi-Vis Vests
MRO Mug
$750
32oz Water Bottle
Throw Blanket
30 piece Hex Set
Telescopic Pick Up
$1,250
Golf Cooler
11-in-1 Screw Driver Set
Gorilla Grip Knee Pad
John Deere Oilskin Hat
$2,500
Igloo 1/2 Gallon Jug
Rechargable Headlamp
Larix Trucker Hat
$5,000
Igloo 10 Gallon Cooler
Igloo Party Bucket Cooler
Klein Tools Speaker
Klein Tools 8-in-1
$7,500
GX-6F Pro Golf Range Finder
Bushnell Outdoorsman Speaker
Jaeger 24px Ratcheting Wrench Set
Aspen Beverage Bucket
SKU: 286716
Arived with the readout actully working
This one worked. Second one I ordered, one from another supplier. First one was dead. Battery is supposed to last for 5 years, it's an "always on" setup. Mine first one did last the 5 years. I use this on my milling machine powered by a VFD.
Read more