Red Lion Controls TCU11108 TCUN4RSP4-20mAAL1&2

MODEL TCU11108

SKU

287366

WEIGHT

2.000 lb

UOM

each

Contact supplier for technical support on: 877-432-9908

$579.00 Each

Prices are subject to change

FREE SHIPPING ON ORDERS OVER $1

Select Quantity

GET A QUOTE

Free Gift with this product

Typically Ships in: 1 day

Returnable: See conditions

Description

The TCU Controller accepts signals from a variety of temperature sensors (thermocouple or RTD elements), precisely displays the process temperature, and provides an accurate output control signal (time proportional, linear, or valve positioning) to maintain a process at the desired control point. A comprehensive set of easy to use steps allows the controller to solve various application requirements.

The controller can operate in the PID control mode for both heating and cooling. On-demand auto-tune establishes the tuning constants. The PID tuning constants may be fine-tuned by the operator at any time and locked out from further modification. The controller employs a unique overshoot suppression feature that allows the quickest response without excessive overshoot. The unit can be transferred to operate in the manual mode, providing the operator with direct control of the output. The controller can also be programmed to operate in the ON/OFF control mode with adjustable hysteresis.

Dual 4-digit displays allow viewing of the process temperature and setpoint simultaneously. Front panel indicators inform the operator of the controller and output status. Replaceable and interchangeable output modules (Relay, SSR Drive, or Triac) can be installed for the main control output, alarm output(s), cooling output, and Valve Positioner outputs.

Optional dual alarms can be configured to activate according to a variety of actions (Absolute HI or LO, Deviation HI or LO, Band IN or OUT, Heater Break, and Valve Fail Detect) with adjustable hysteresis. A standby feature suppresses the output during power-up until the temperature stabilizes outside the alarm region. An optional secondary output is available (for processes requiring cooling) that provides increased control accuracy and response.

A linear 4 to 20 mA or 0 to 10 VDC output signal is available to interface with actuators, chart recorders, indicators, or other controllers. The type of Linear DC output is determined by the model ordered. The output signal can be digitally scaled and selected to transmit one of the following: % output power, process temperature value, process temperature value deviation or setpoint value. For Linear DC control applications, the adjustable output demand dampening, output deadband, and output update time parameters expand the versatility of the TCU to final control devices.

The optional Second Analog Input (0 to 20 mA DC) can be configured as a Remote Setpoint signal or as a Secondary Process signal. Configuration of the Second Analog Input as a Remote Setpoint signal allows ratio control, master setpoint/multiple slave operation, and the ability to cascade the TCU with another controller (External Cascade). Configuration of the Second Input as a Secondary Process signal allows operation as a two-process cascade controller within a single unit (Internal Cascade). In either control mode, parameters are provided to scale, configure, communicate and monitor the activity of both analog inputs. A square law linearizer function can be used to linearize signals derived from flow transmitters.

A NEMA 4X/IP65 rated bezel is available for wash down applications and similar environments, when properly installed. Modern surface-mount technology, in-house assembly and testing, and high immunity to noise interference makes the controller extremely reliable in industrial environments.

Note: Output Modules are NOT supplied with the controller. When specifying the controller, be sure to purchase the appropriate output module for the Main Control Output and if necessary, the alarm output(s), the secondary output, and valve positioner outputs.

The Logic/SSR Drive Module is a switched DC source, intended to drive the DC input of an SSR power unit. It should never be connected to line voltage.

All modules are packaged separately and must be installed by the user.

Specifications
  • 97 mm x 50 mm
  • Dual 4 Digit, 0. 4" (10 mm) LED, 0. 3" (7. 6 mm) LED
  • Thermocouple and RTD Input
  • Dual Alarms
  • Remote Setpoint Input
  • Linear 4 to 20 mA Output
  • NEMA4X/IP67 Front Panel
Accessories
OMD00000OMD Relay Module for PCU, PSC, TCU and TSC
OMD00001OMD Triac Module
OMD00003OMD Logic/SSR Drive Module

SKU: 286716

Arived with the readout actully working

This one worked. Second one I ordered, one from another supplier. First one was dead. Battery is supposed to last for 5 years, it's an "always on" setup. Mine first one did last the 5 years. I use this on my milling machine powered by a VFD.

Read more

When you get to checkout, you’ll be able to select a free gift! Depending on the cart value, you’ll be shown relevant gifts your order qualifies for.

$500

MRO Hat
MRO Golf Balls
MRO Hi-Vis Vests
MRO Mug

$750

32oz Water Bottle
Throw Blanket
30 piece Hex Set
Telescopic Pick Up

$1,250

Golf Cooler
11-in-1 Screw Driver Set
Gorilla Grip Knee Pad
John Deere Oilskin Hat

$2,500

Igloo 1/2 Gallon Jug
Rechargable Headlamp
Larix Trucker Hat

$5,000

Igloo 10 Gallon Cooler
Igloo Party Bucket Cooler
Klein Tools Speaker
Klein Tools 8-in-1

$7,500

GX-6F Pro Golf Range Finder
Bushnell Outdoorsman Speaker
Jaeger 24px Ratcheting Wrench Set
Aspen Beverage Bucket

Reviews

SKU: 286716

Arived with the readout actully working

This one worked. Second one I ordered, one from another supplier. First one was dead. Battery is supposed to last for 5 years, it's an "always on" setup. Mine first one did last the 5 years. I use this on my milling machine powered by a VFD.

Read more

Return policy

Item must be unused.

Item must be in it's original package.