N62E-84 Contactor Relay
N62E-84
ABB N62E-84 Contactor Relay | N62E-84MODEL N62E-84
$94.81 Each
Prices are subject to change
FREE SHIPPING ON ORDERS OVER $1
Select Quantity
Orders over $500 qualify for a Free Gift
Typically Ships in: 1 day
Returnable: Yes
BV certificate
BV_2634H09651C0
CB certificate
CB_FR_602227B
CCC certificate
CCC_2003010304088236
Climatic withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Coil operating limits
(acc. to IEC 60947-5-1) 0.85 ... 1.1 x Uc (at 55 C) C
Connecting capacity auxiliary circuit
Flexible with Cable End 0.75 ... 2.5 mm Rigid Cable 1 ... 4 mm
Conventional free-air thermal current (Ith)
acc. to IEC 60947-5-1, q = 40 C 16 A
CSA certificate
CSA_1041746
cUL certificate
UL_110105E48139A
Data sheet, technical information
1SBC100122C0202_Ch03
Declaration of conformity - CE
1SBD250808U1000
Degree of protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
DNV certificate
DNV-GL_TAE00000TY
ETIM 4
EC000196 - Contactor relay
ETIM 5
EC000196 - Contactor relay
ETIM 6
EC000196 - Contactor relay
GL certificate
DNV-GL_TAE00000TY
GOST certificate
GOST_POCCFRME01B03022
LR certificate
LRS_9830010E2
Max mechanical switching frequency
6000 cycles per hour
Max operating altitude permissible
3000 m
Mechanical durability
> 20 million
Number of auxiliary contacts NC
2
Number of auxiliary contacts NO
4
Object classification code
K
Rated control circuit voltage (Uc)
50 Hz 110 V 60 Hz 110 120 V
Rated frequency
Supply Circuit 50 Hz Supply Circuit 60 Hz
Rated impulse withstand voltage (U imp)
8 kV
Rated insulation voltage (Ui)
acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V acc. to UL/CSA 600 V
Rated operational current AC-15 (Ie)
(220 / 240 V) 4 A (24 / 127 V) 6 A (380 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
Rated operational current DC-13 (Ie)
(125 V) 0.55 / 69 A (24 V) 6 / 144 A (250 V) 0.3 / 75 A (48 V) 2.8 / 134 A (72 V) 1 / 72 A
Rated operational voltage
Main Circuit 690 V
Rated short-time withstand current (Icw)
for 0.1 s 140 A for 1 s 100 A
RINA certificate
RINA_ELE128713XG002
RMRS certificate
RMRS_0507015250
RoHS information
1SBD350056R1000
RoHS status
Following EU Directive 2002/95/EC August 18, 2005 and amendment
Short-circuit protective devices
gG Type Fuses 10 A
Terminal type
Screw terminals
UL certificate
UL_110105E48139A
- N... Contactor Relays Are Used For Switching Auxiliary Circuits And Control Circuits - Poles: 8-Pole Contactor Relays (Mechanically Linked Contact Elements Available) The Width Of 8-Pole Devices Is Identical To That Of 4-Pole Devices Only The Depth Is Increased - Control Circuit: Ac Operated With Laminated Magnet Circuit - Accessories: A Wide Range Of Accessories Is Available.
Only The Depth Is Increased
- Control Circuit: Ac Operated With Laminated Magnet Circuit
- Accessories: A Wide Range Of Accessories Is Available.
Standards: Devices complying with international standards IEC 947-5-1 / 947-4-1 and European standards EN 60 947-5-1 / 60 947-4-1. Electromagnetic compatibility (EMC) according to amendment A11 to IEC 947-1; EN 60 947-1 and amendment 2 to IEC 947-4-1
Ambient air temperature: Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 C Near Contactor for Operation in Free Air (Uc) -40 ... +70 C Close to Contactor for Storage -60 ... +80 C
Coil consumption: Pull-in at Max. Rated Control Circuit Voltage 50 Hz 70 VA Pull-in at Max. Rated Control Circuit Voltage 60 Hz 80 VA Holding at Max. Rated Control Circuit Voltage 60 Hz 8 VA Holding at Max. Rated Control Circuit Voltage 60 Hz 2 W Holding at Max. Rated Control Circuit Voltage 50 Hz 8 VA Holding at Max. Rated Control Circuit Voltage 50 Hz 2 W Average Holding Value 50 / 60 Hz 8 VA Average Holding Value 50 / 60 Hz 2 W Average Pull-in Value 50 Hz 74 VA Average Pull-in Value 60 Hz 70 VA
Operate time: Between Coil Energization and NO Contact Closing 10 ... 26 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms Between Coil De-energization and NC Contact Closing 9 ... 16 ms Between Coil Energization and NC Contact Opening 7 ... 21 ms
Resistance to shock acc. to IEC 60068-2-27: Shock Direction A 20 g Closed, Shock Direction B1 10 g Open, Shock Direction B1 5 g Shock Direction B2 15 g Shock Direction C1 20 g Shock Direction C2 20 g
When you get to checkout, you’ll be able to select a free gift! Depending on the cart value, you’ll be shown relevant gifts your order qualifies for.
$500
MRO Hat
MRO Golf Balls
MRO Hi-Vis Vests
MRO Mug
$750
32oz Water Bottle
Throw Blanket
30 piece Hex Set
Telescopic Pick Up
$1,250
Golf Cooler
11-in-1 Screw Driver Set
Gorilla Grip Knee Pad
John Deere Oilskin Hat
$2,500
Igloo 1/2 Gallon Jug
Rechargable Headlamp
Larix Trucker Hat
$5,000
Igloo 10 Gallon Cooler
Igloo Party Bucket Cooler
Klein Tools Speaker
Klein Tools 8-in-1
$7,500
GX-6F Pro Golf Range Finder
Bushnell Outdoorsman Speaker
Jaeger 24px Ratcheting Wrench Set
Aspen Beverage Bucket