DTGA0112S Drive Isolation Transformer Three Phase 60 Hz 460 Delta Primary Volts 230Y/133 Secondary Volts
MODEL DTGA0112S
Contact supplier for technical support on: 800 334 5214
$1,686.22 Each
Prices are subject to change
FREE SHIPPING ON ORDERS OVER $1
Select Quantity
Free Gift with this product
Typically Ships in: 3 days
Returnable: See conditions
460 Delta Primary Volts - 230Y/133 Secondary Volts - All Acme Drive Isolation Transformers (DITs) above 7.5kVA are wound with strip windings to ensure the lowest possible eddy current losses. All our DITs use a three leg wound core. This superior design has very low losses and quiet operation. Both of these features combine to significantly reduce losses and operation costs compared to other types of constructions. All Acme DITs up to and including the 220kVA have copper terminations. The transition from aluminum strip coil conductors to copper terminations is accomplished by a bonding process known as "Koldwelding" This process has been used by Acme for over 25 years to provide a trouble-free, permanent bonding of the two metals.
- 7.5–20.0 kVA are encapsulated, UL 3R
- 3-Phase 60 Hertz
- 180°C and 220°C insulation systems
- Acme’s reinforced core assemblies enhance quiet operation
- Nominally 6% impedance
- Designed for use with AC, adjustable frequency or DC drives
- Full capacity taps are featured on all units. On 7.5 through 20 kVA units, taps are 1-5% ANFC and 1-5% BNFC.
- Full range of kVA ratings cover all standard drive systems
- Ample wiring compartment for easy cable entry
- Optional wall mounting brackets for certain sizes
- Stress relief: Acme uses strip conductors (above 7.5 kVA) instead of wire for a DIT series that easily accommodates the severe electrical and mechanical stresses found in today’s AC & DC motor drives. The inherent excellent line isolation of these transformers is further enhanced with the extra protection of Acme’s Electrostatic Shield — free in all DIT’s.
- Lower losses: The harmonic currents generated by AC & DC drives increase eddy current losses (heat) in transformer windings. The thicker the winding conductor, the greater the losses. Acme uses one turn per layer of thin strip conductor which provides lower eddy current losses than comparable wire wound units. Lower losses = cooler operation and longer transformer life.
- Reduced short circuit forces: Strip windings minimize axial short circuit forces that can cause mechanical displacement of the windings under fault conditions. For extra protection all designs 7.5 kVA and above use primary and secondary coils of equal axial length. This feature tends to negate axial short circuit forces, further improving transformer life expectancy.
Out of Package Height (in) | 18.860 |
---|---|
Out of Package Width (in) | 20.300 |
Out of Package Length/Depth (in) | 9.030 |
Out of Package Weight (lbs) | 265.000 |
SKU: 885669
Transformer
Excellent. Exactly what we needed. Quick shipping and great pricing. Highly recommend.
Read moreWhen you get to checkout, you’ll be able to select a free gift! Depending on the cart value, you’ll be shown relevant gifts your order qualifies for.
$500
MRO Hat
MRO Golf Balls
MRO Hi-Vis Vests
MRO Mug
$750
32oz Water Bottle
Throw Blanket
30 piece Hex Set
Telescopic Pick Up
$1,250
Golf Cooler
11-in-1 Screw Driver Set
Gorilla Grip Knee Pad
John Deere Oilskin Hat
$2,500
Igloo 1/2 Gallon Jug
Rechargable Headlamp
Larix Trucker Hat
$5,000
Igloo 10 Gallon Cooler
Igloo Party Bucket Cooler
Klein Tools Speaker
Klein Tools 8-in-1
$7,500
GX-6F Pro Golf Range Finder
Bushnell Outdoorsman Speaker
Jaeger 24px Ratcheting Wrench Set
Aspen Beverage Bucket
SKU: 885669
Transformer
Excellent. Exactly what we needed. Quick shipping and great pricing. Highly recommend.
Read moreItem must be unused.
Item must be in it's original package.
20% Restocking, shipping and handling fees may apply to any return with this manufacturer.
For more information please consult https://www.mrosupply.com/page/returnwarranty-policy/